15 Données techniques
ELECTRICAL SPECIFICATIONS
Type
Electric heater
( optional )
Capacity setting
Phase
Power supply (1)
Frequency
Voltage
Running Current (back-up heater)
Current
Zmax (back-up heater)
Minimum S
value (8)
sc
Running Current
backup heater
Minimum
Voltage range
(4)
Maximum
type of wires
power supply for
Wiring
back up heater
connections
quantity of wires
Communication
type of wires
cable
quantity of wires
type of wires
User interface
quantity of wires
Preferential kWh
quantity of wires
rate power
supply
type of wires
quantity of wires
Electricity meter
type of wires
quantity of wires
domestic hot
type of wires
water pump
quantity of wires
for connection with
type of wires
R6T
quantity of wires
for connection with
type of wires
A3P
quantity of wires
for connection with
M2S
type of wires
for connection with
quantity of wires
optional FWXV*
type of wires
(demand input and
output signal)
quantity of wires
bfor connection with
type of wires
bottom plate heater
Notes
(1) Above mentioned power supply of the hydro box is for the backup heater only. The Switch box & pump of the hydrobox are supplied via the outdoor unit.
(3) Select diameter and type according to national and local regulations
(4) For more details of the voltage range and current refer to installation manual
(5) Voltage: 230V / Maximum current: 100mA / Minimum 0,75mm²
(6) Depends on thermostat type, refer to installation manual
(7) Wire included in option *KHW*
(8) In accordance with EN/IEC 61000-3-11(*), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys(***) ≤ Zmax
(9) Equipment complying with EN/IEC 61000-3-12 (**)
(*) : European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
(**) : European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase.
(***) : System impedance
15.8

Plage de fonctionnement

15.8.1 Plage de fonctionnement: unité extérieure
outdoor temp. (°CDB)
46
10
5
22
outdoor temp. (°CDB)
35
0
–20
–25
15 18 25
outdoor temp. (°CDB)
35
0
–20
15 18 25
40
Guide de référence installateur
101
3V
9W
kW
3
6
3
6
6
1~
3~
1~
1~
3~
Hz
50
50
V
230
230
230
400
8,7
15,1
13
26
A
13
Ω
-
-
-
0,29
-
kVA
-
-
-
(9)
-
13
A
13
15,1
26
8,7
V
207
207
207
207
360
V
253
253
253
253
440
3G
4G
3G
3G
4G/5G
Note (3)
Note (3)
Note (3)
Note (3) Note (3)
3
2,5 mm²
2
0,75 mm² till 1,25 mm² (max length 500 m)
power : 2
signal : 2
power : 6,3 A note (3)
signal : 0,75 mm² till 1,25 mm²(max length 50 m)
2
Minimum 0,75 mm² (5VDC pulse detection)
2
Minimum 0,75 mm² (2A inrush, 1A continuous)
2
Minimum 0,75 mm²
Note (6)
Note (3) and (5)
3G
Note (3) and (5)
4
100 mA, minimum 0,75 mm²
2
Note (3)
INDOOR:
AA-SERIES
AB-SERIES
BA-SERIES
BB-SERIES
CA-SERIES
leaving evaporator
water temperature (°C)
(
)
*
leaving condensor
water temperature (°C)
55
(
)
*
leaving condensor
water temperature (°C)
55
9
3~
400
13
-
-
13
360
440
4G/5G
Note (3)
INDOOR:
CA-SERIES
outdoor temp. (°CDB)
46
18
10
5
outdoor temp. (°CDB)
25
10
0
–15
–20
–25
LEGEND:
:
ONLY BACKUP HEATER OPERATION
(NO OUTDOOR UNIT OPERATION)
:
OUTDOOR UNIT OPERATION IF SETPOINT ≥25°C
:
OPERATION OF OUTDOOR UNIT POSSIBLE, BUT NO
GUARANTEE OF CAPACITY.
(IF OUTDOOR TEMPERATURE < –20°C or < –25°C OUTDOOR UNIT WILL STOP)
(INDOOR UNIT AND BACKUP HEATER OPERATION WILL CONTINUE)
:
PULL DOWN AREA
REMARK: FOR RESTRICTED POWER SUPPLY CONDITION MODE
OUTDOOR UNIT, BOOSTER HEATER AND BACKUP HEATER
CAN ONLY OPERATE SEPERATELY.
(
)
*RLQ units include special equipment (insulation, heater sheet, ...)
*
to ensure good operation in areas where low ambient temperature
can occur together with high humidity conditions. In such
conditions the *RHQ models may experience problems with severe
ice build up on the aircooled coil.
In case such conditions ara expected, the *RLQ must be
installed instead. These models contain countermeasures
(insulation, heater sheet, ...) to prevent freeze up.
3D077571_A page 2
leaving evaporator
water temperature (°C)
13
22
50
leaving evaporator
water temperature (°C)
15 18 25 30
45
50
55
3TW60813-1A
EHVH/X04+08 + ERLQ004~008
Daikin Altherma - basse température Bibloc
4P313775-1 – 2012.05