1.2. Feature description
SPASCIANI RN series self-contained breathing apparatuses are classified, in accordance with the EN 137:2006
standard, as follows:
- Type 1: device for industrial use;
- Type 2: apparatus for fire fighting.
The models of the RN series available are as follows:
RN T1
Type 1 self-contained open circuit breathing apparatus shoulder mounted "light" version (harness
with no padding and demande valve with one piece hose)
RN
Type 1 self-contained open circuit breathing apparatus shoulder mounted
RN BIBO
Type 1 self-contained open circuit breathing apparatus with two cylinders shoulder mounted
RN FR
Type 2 self-contained open circuit breathing apparatus shoulder mounted
Type 2 self-contained open circuit breathing apparatus shoulder mounted "light" version (harness
RN FR T2
with no padding and demande valve with one piece hose)
RN FR BIBO
Type 2 self-contained open circuit breathing apparatus with two cylinders shoulder mounted
Each apparatus shall be assembled in different approved configuration (e.g. steel or composite cylinder, TR 82 or TR 2002
full face mask with type A or BN demand valve, different accessories) as described in the Configurator (See table 3).
1.3. Intended use, limitations
SCBAs RN T1, RN e RN BIBO, complete with cylinder, mask and demand valve in the combinations described by the
Configurator, are Type 1 apparatuses, designed for use in an emergency and in industrial applications that require a
high level of respiratory protection, in very polluted environments or with oxygen deficiency areas.
The RN T1 version is of economic type (masks and cylinders are in limited models, medium pressure hose in a single
piece). RN BIBO were specially designed for those that need long duration SCBA. These pieces of equipment are
suitable for long-lasting interventions for survey and inspection purposes. Due to heavy weight of the sets with 9 l
cylinders, only persons in good health and in good physical conditions must be allowed to use them.
RN FR, RN FR T2 and RN FR BIBO are Type 2 apparatuses and they are specially designed for fire-fighting. They were
subject to the Flame Engulfment test as per EN 137:2006 standard and they are therefore suitable for use where the
risk of a flash over is high.
It is extremely important to follow the instructions for use reported on this booklet and it is strictly forbidden to use
the device for purposes other than the ones described in these instructions.
The devices described herein ARE NOT SUITABLE FOR UNDERWATER USE even if their functions remain unaffected
when submerged in water for a short period of time.
Their autonomy depends on the air reserve available. Refer to Table 1 for more information.
Always use breathable air according to the EN 12021 standard.
2. DETAILED DESCRIPTION
The breathing apparatuses RN series consist of the following elements:
Carrying system
Air pressure cylinder/s
Pressure reducer
High pressure gauge with connection hose
Demand valve with audible warning device
Full face mask
and any
Accessories
Reference figures:
Fig.1 for RN T1 and RN FR T2
Fig.2 for RN, RN FR
Fig.3 for RN BIBO, RN FR BIBO
Fig.4 for the pressure reducer
Fig.5 for the demand valve
Fig.6 for the full face mask
2.1. Carrying system (pos. A in fig. 1,2,3)
Pag. 14 / 55