OADM 20I6x41, OADM 20I6x60,
OADM 20I6x72
OADM 20I6x80, OADM 20I6x81
OADM 21I6x80, OADM 21I6x81
t1 is the max. time after a high signal on the synch. input of S1 until the analog value will be held. This value
will be held as long the signal on the synch. input is high.
The min. time between the high signal of S1 and the low signal of S2 is t1, also. In this case, an optical
influence between the sensors is not possible.
t2 is the time until the analog signal is ready after a low signal on the synch. input of S2. This time depends
on the reflectivity of the object and if the reflectivity changes during the hold time.
Input circuit
sync in
low: 0 .. 2V
27kΩ
high: 12 .. 28V
10kΩ
BA_OADM20I6_21I6_most.doc
12.06.2017
t1
t2
< 0.9 ms
0.5...2.7 ms
< 2.8 ms
0.5...8.4ms
< 4 ms
1...12 ms