Télécharger Imprimer la page

Perel LEDA402 Série Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
4. Connect the power cable [4] to a suitable junction box (not incl.). Make
sure the connection is properly earthed. Make sure there is no strain on
the cable; leave sufficient slack.
Warning: if the power cable is damaged, it must be replaced by the
manufacturer, his service agent, or a similar qualified person in order to
avoid any hazard.
5. To point the lamp in the desired direction: loosen the hinges [2] using a
hex key.
6. Tilt the lamp in the desired angle and tighten the hinges.
7. Cleaning and Maintenance
All screws should be tight and free of corrosion.
The housing, the visible parts, the mounting supports and the installation
location (e.g. ceiling, suspension, trussing) should not be deformed,
modified or tampered with; e.g. do not drill extra holes in mounting
supports, do not change the location of the connections...
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a
qualified technician maintain the device.
If the protective glass [3] is damaged, disconnect the lamp immediately
from the mains. Have it repaired immediately by a qualified technician.
Do not use the lamp with a cracked or broken protective glass.
This luminaire does not have a built-in device to disconnect it from the
electric mains. Make sure to electrically isolate the luminaire before
installation or maintenance activities are performed.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol
or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
V. 01 – 16/06/2014
LEDA402 Series
N = neutral, blue
E = earth, yellow/green
L = line, brown
7
©Velleman nv

Publicité

loading