Mitsubishi Electric CITY MULTI PLFY-P05NFMU-E Manuel D'utilisation page 12

Indoor unit
Masquer les pouces Voir aussi pour CITY MULTI PLFY-P05NFMU-E:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

. Operation
Direct/Indirect setting
: Direct
: Indirect
: Indirect
: Direct
Select:
Angle
Outlet
F1
F2
F3
F4
i-See button ( ireless remote controller)
1 Each time
is pressed during operation, the setting changes in
Display
Setting
OFF
Direct
When the setting is changed from OFF to Direct or Indirect, the vane
setting changes to "Auto". This setting is applied collectively to all of the
vanes.
.6.
Energy saving option
Energy saving option
No occupancy energy save
Room occupancy energy save
No occupancy Auto-OFF
Setting display:
Cursor
F1
F2
F3
F4
3 When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1] or
[F2] button, and change the setting
with the [F4] button.
After changing the settings for all of
the air outlets, press the [SELECT]
button to save the settings.
* In order to enable this function,
the airflow direction must be set
to "Auto".
Indirect
1 Select the desired menu with the
[F1] or [F2] button.
No occupancy energy save
If there are no persons in the room
for 60 minutes or more, energy-
saving operation equal to 2 °C (4 °F)
is performed.
Room occupancy energy save
If the occupancy rate decreases to
approximately 30% of the maximum
occupancy rate, energy-saving
operation equal to 1 °C (2 °F) is
performed.
No occupancy Auto-OFF
If there are no persons in the
room for the set amount of time
(60–180 minutes), the operation
is automatically stopped.
2 When No occupancy energy save
Energy saving option
No occupancy energy save
Cooling/Heating
Select:
F1
F2
F3
F4
Energy saving option
Room occupancy energy save
Cooling/Heating
Select:
F1
F2
F3
F4
3 When No occupancy Auto-OFF is
Energy saving option
No occupancy Auto-OFF
120
min.
Select:
Time
F1
F2
F3
F4
4 The message at left will appear
18:47 Thu
Shut down by
No Occupancy Auto-OFF
31/Dec AM12:59
F1
F2
F3
F4
or Room occupancy energy save
is selected
Select the setting with the [F4]
button.
OFF
Cooling only
Heating
only
Cooling/Heating
After changing the setting, press
the [SELECT] button to save the
setting.
OFF: The function is disabled.
Cooling only: The function is
enabled only during cooling mode.
Heating only: The function is
enabled only during heating mode.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
selected
Set the time with the [F3] or [F4]
button.
(the operation will not stop
automatically).
60 – 180: The time can be set in
10-minute increments.
if the operation was stopped
automatically by the No occupancy
Auto-OFF setting.