Timer - Mitsubishi Electric CITY MULTI PLFY-P05NFMU-E Manuel D'utilisation

Indoor unit
Masquer les pouces Voir aussi pour CITY MULTI PLFY-P05NFMU-E:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

. Operation
.6.4 Seasonal airflow function
Seasonal airflow
Seasonal airflow
Cooling/Heating
Select:
F1
F2
F3
F4
Notes:
Any person at the following places cannot be detected.
Along the wall on which the air conditioner is installed
Directly under the air conditioner
here any obstacle, such as furniture, is between the person and
the air conditioner
A person may not be detected in the following situations.
Room temperature is high.
A person wears heavy clothes and his/her skin is not exposed.
A heating element of which temperature changes signi cantly is
present.
Some heat sources, such as a small child or pet, may not be sensed.
A heat source does not move for a long time.
The D i-See sensor operates once approximately every
to measure the floor temperature and detect persons in the room.
The intermittent operating sound is a normal sound produced when
the D i-See sensor is moving.
hen 1 MA Remote Controller is used to control multiple indoor
units, No occupancy Auto-OFF cannot be used.

4. Timer

Timer functions are different by each remote controller.
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.
1 Select the setting with the [F4]
button.
After changing the setting, press
the [SELECT] button to save the
setting.
OFF: The function is disabled.
Cooling only: When the thermostat
turns off during cooling mode, the
vanes move up and down.
Heating only: When the thermostat
turns off during heating mode,
the vanes move to the horizontal
airflow direction to circulate the air.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
* In order to enable this function,
the airflow direction must be set
to "Auto".
minutes
Notes:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1.
hile the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
. In heat mode, when room temperature is higher than the tem-
perature setting.
.7. Ventilation
For LOSSNAY combination
The following 2 patterns of operation is available.
Notes: (for wireless remote controller)
Running the ventilator independently is not available.
No indication on the remote controller.

Publicité

Table des Matières
loading

Table des Matières