Preselection of the speed:
The speed can be set in two stages. The switch (12) for this is located on
the motor.
Power On / Off:
Moving the mixing unit in and out:
Prepare mixing as follows:
Start the mixing station always in empty condition or only filled with water.
Always fill with water first. Fill the mixing material through the feed chute
(2) while the machine is running.
We recommend the use of speed stage I to start mixing and switching to
stage II when all components have been filled in.
For mixing with little dust, a vacuum cleaner (Dust class M) is connected to
the corresponding connection nozzle (6).
Observe the processing directives of the material manufacturers.
For mixing of low-viscous materials (e.g. self-flowing levelling
compounds), the supplied wiper must be attached to the mixing
paddle. The wiper prevents that mixing material remains sticking to the
Use
Stage I = 20/250 rpm
Stage II = 36/450 rpm
Mixing in continuous operation always should be done at
stage II to provide sufficient cooling air to the motor.
For power ON, the mixing unit must be lowered
completely and the slide must be locked.
For power ON, switch the switch (11) up (ON).
For power OFF, switch the switch (11) down (OFF).
The slide is locked automatically in each end position.
This means when the mixing unit has been moved completely
into the bucket as well as when it has been moved out
completely for removal of the bucket car.
The locking knob (7) must be pulled out to move the mixing unit
in or out.
Always check that the slide is locked securely in the
respective position.
18