Pentair Hydromatic FG100-A1 Notice D'utilisation page 11

Système de secours à batterie
Masquer les pouces Voir aussi pour Hydromatic FG100-A1:

Publicité

Les langues disponibles

Les langues disponibles

Installation
TABLE V - 8 Amp Charger Error Table
Error Description
The Battery Failed
Pre-Qualification Test
Battery Over-Voltage
Charge Time Monitor
Excessive Battery
Drain
Reverse Battery
Connection
Battery Overheated
Charging Error
TABLE VI - 8 Amp Charger Error Light Indications
NOTE: This chart identifies light codes indicating various char-
ger error modes. It only applies when the 'Charger Mode' light
flashes YELLOW/GREEN alternately. The light codes listed here
DO NOT relate directly to the legends on the charger housing
A.C. Power
Status
Flashing
Flashing
Flashing
Flashing
Off
Off
Off
"Silence Alarm/Reset" Rocker Switch:
Push the LEFT side of the rocker switch on the front of the
charger to silence the alarm. NOTE: This will NOT silence the
alarm when the battery is below 8.2 volts or the system is in
ERROR mode.
Possible Causes
The battery is highly sulfated
The charger is connected to a
six-volt battery
The Charger is connected to a
24 Volt Battery
Battery took too long to complete
its charge:
A. Load applied (e.g. the pump motor
started) during charging
B. The battery ampere-hour rating
is too large (Max. 130 ampere-hours)
Pump motor ran during charging
(that is, with the main A.C. power ON),
causing the system to shut down
Charger is connected backwards
to the battery. (That is, Charger (+) to
Battery (-) and vice versa)
Cells in an old battery may
deteriorate with age
An internal error occurred in the charger
during one of the charging stages
Pump Run
Alarm
Status
Silence
Off
Off
Off
Flashing
Flashing
Off
Flashing
Flashing
Off
Flashing
Flashing
Off
Flashing
Flashing
Fix
Replace the battery with a 12-Volt deep-cycle
marine battery
Replace the battery with a 12-Volt deep-cycle
marine battery
Replace the battery with a 12-Volt deep-cycle
marine battery
Be sure pump cannot start during charging;
reset the charger
Replace with correct size battery (see Page 4)
Check primary sump pump. The BBU generally
runs only when the main A.C. power is out.
If there has not been any power outage and the BBU
has run, the primary pump itself may have failed
Reconnect Charger (+) to Battery (+)/(-) to (-)
Replace battery with a 12-Volt deep-cycle
marine battery
Unplug the charger for 10 seconds and then plug it
in again. If error occurs again, refer to Table VI, below
(A.C. Power Status, Pump Run Status, Alarm Silence, etc.). The
legends on the charger apply ONLY when the 'Charger Mode'
light is NOT flashing yellow/green.
LED Status
Charge
Mode
Flashing Yellow/Green
Flashing Yellow/Green
Flashing Yellow/Green
Flashing Yellow/Green
Flashing Yellow/Green
Flashing Yellow/Green
Flashing Yellow/Green
Push the RIGHT side of the rocker switch to reset the 'Pump
System Status' LED after the pump has run, or to reset the sys-
tem from an error mode. When you reset the system, the char-
ger will start its diagnostic procedure (pre-qualification test,
etc.) from the beginning. If the cause of the ERROR mode is not
corrected, the system will go into the ERROR mode again.
11
Error Mode
Battery Overheated
Charge Time Monitor
Excessive Battery Drain
Failed Pre-Qualification Test
Battery Over-Voltage
Reverse Battery Connection
Output Over-Current