Technical Data; General Precautions; Installation Regulations - LA NORDICA FLO' Installation, Entretien Et Instructions D'utilisation

Masquer les pouces Voir aussi pour FLO':
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. TECHNICAL DATA

Definition in according to:
Constructive system
Nominal thermal power in kW
Efficiency in %
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Depression by rating calorific value in Pa - wood
Hourly wood consumption in Kg / h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s - wood
Exhaust gas temperature in °C - wood
Outer air inlet Ø in mm (minimum surface cm
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
m
heatable (30 kcal/h x m
3
Electric consumption (W) max
(#) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
stoves is:favourable type of building (30 Kcal/h x m
(50 Kcal/h x m
).
3
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.

2. GENERAL PRECAUTIONS

La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole. La NORDICA S.p.A. declines any responsibility for the product that has been modified without written
authorisation as well as for the use of non-original spare parts.
This appliance is not suitable for the use of inexperienced people (included children) or with physical, sensorial and mental reduced
capacities. They have to be controlled and educated in the use of the appliance from a responsible person for their security. The children
have to be controlled to be sure that they would not play with the appliance. (EN 60335-2-102/7.12).
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules.
NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A. cannot be held responsible for lack of
respect for such precautions.

3. INSTALLATION REGULATIONS

Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for final installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing flue of the house. The junction
must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing the appliance, carry out the following checks:
• UPPER smoke output – REAR smoke output
• verify if your structure can support the weight of the appliance. In case of insufficient carrying capacity it is necessary to adopt
appropriate measures, La NORDICA responsibility is limited to the supply of the appliance.
• Make sure that the floor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of flammable
16
_EN
)
2
)
3
(#)
); less favourable type of building (40 Kcal/h x m
3
FLÒ
EN 13240
1
8,3
85
150
4 - 200x200 Ø200
12 (1,2 mm H
O)
2
2,3
0,09 - (1136 mg/Nm
)
3
5,9
233
120 (100 cm
)
2
326 x 347
300 x 400 x 360
/
Movable - flat
1200
678
560
145
Chapter FIRE SAFETY
238
50
); unfavourable type of building
3
FLO'
7194501

Publicité

Table des Matières
loading

Table des Matières