VII BEFORE FIRST USE
Upon receipt of the goods, check the packaging for integrity and open it. If the packaging is damaged, please
contact your transport company and distributor within 3 days, and document the damages as detailed as
possible. Do not turn the package upside down! When transporting the package, please ensure that it is kept
horizontal and stable. Please keep all packaging materials (cardboard, plastic tapes and Styrofoam), so that in
case of a problem, the device can be sent back to the service centre in the best possible condition.
VIII HOW TU USE
Prepare the room as per the description provided in this manual and energise the device.
AIRCLEAN 10G (5050) | AIRCLEAN 7G (5051) | AIRCLEAN 20G (5053) | AIRCLEAN 15G (5054):
Continuous operation mode: activate ozone treatment with ON/Off button. The display will show
"HOLD ON". The device will operate continuously.
Timer mode operation: activate the device with „Timer" button. The display will show "TIMER
OFF UNTIL" as well as time in hours and minutes until deactivation of the device. The time can be
freely adjusted in the range between 5 minutes and 24 hours. Timer off modification: upon activating
the device with „Timer" button press "Set" button. Preset time will start blinking, use "Up"/
"Down" buttons to set the desired time after which the device is to deactivate and then press "Set"
again – the modification will be stored in the device and the device will activate.
Auto mode operation: turn the device on with "Auto" button, the display will show "ON" / device
operation time and program reference number P1, P2 or P3 (switch between programs by pushing the
"Auto" button in sequence). The device is delivered with three default programs:
P1: 10 minute operation / 20 minute pause / 5 rounds
P2: 20 minute operation / 20 minute pause / 5 rounds
P3: 40 minute operation / 20 minute pause / 5 rounds
Operation times / pause and number of rounds can be freely modified in each of these programs.
Modification of operation time, pause and number of rounds:
Operation times / pause and number of rounds can be freely modified in each of these programs. To do this
press the "Set" button while in the program which you wish to modify (P1, P2 or P3). Starting with P1, press
"Set" to move to operation time setting, the display will show "Set Pro. ON" as well as blinking operation
time setting – change it to your desired value using "Up"/"Down" buttons. Press "Set" to move to pause
time setting, the display will show "Set Pro. OFF" as well as blinking pause time setting – change it to your
desired value using "Up"/"Down" buttons. Press "Set" to move to number of rounds setting. The display
will show "Set Pro. ON OFF" as well as blinking number of rounds. Use "Up"/"Down" buttons to set your
desired value and press "Set" to move to modification of program 2 (P2). Use the same procedure for the
remaining programmes. To exit programme modifications, press the "Set" button and hold it until the devices
moves to the first value of previously modified programme – the device will be activated in auto mode with
programme preset operation and pause time values as well as preset number of rounds.
AIRCLEAN 20G-ECO (5052) | AIRCLEAN 7G-ECO (5055)
Use the operation time selector knob to set the desired duration of ozone treatment (60 minutes max.). In
"HOLD" mode the device will operate continuously.
IX CLEANING THE DEVICE
Before cleaning, the device must be disconnected from the power supply source. To keep the device clean, the
device must be cleaned using a soft, dry cloth. Never use brushes or other cleaning tools that may scratch/
damage the device. Remember to prevent water from penetrating inside the device through vents in the
housing of the device. The air filter must be cleaned (vacuumed) regularly.
X TRANSPORTATION AND STORAGE
During transport, the machine should be protected from shaking and falling. Store the machine in a well
ventilated place with dry air and without corrosive gases.
14
XI REGULAR CONTROL OF DEVICE
Regularly check the machine for signs of damage. If the machine is damaged, please stop using it immediately
and contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare following information:
Invoice number and serial number (the latter is to be found on the technical plate on the machine).
If relevant, a picture of the damaged, broken or defective part.
It will be easier for your customer service clerk to determine the source of the problem if you give
a detailed and precise description of the matter. The more detailed your information,
the better customer service will be able to solve your problem rapidly and efficiently!
CAUTION: Never open the machine without the authorization of your customer service. This can lead to
a loss of warranty!
Rev. 26.04.2017