Product name:
Art. No.:
5050
5051
5052
Model:
AIRCLEAN
AIRCLEAN
AIRCLEAN
10G
7G
20G-ECO
Ozone output: 10000
7000 mg/h
20000 mg/h
mg/h
Fan output:
170 m3/h
170 m3/h
170 m3/h
UV Lamp:
118 mm, 4
118 mm, 4
135 mm, 4
W, 254 nm
W, 254 nm
W, 254 nm
Voltage /
110 W
98 W
205 W
Frequency:
Spannung /
Frequenz:
IV RECOMMENDED DURATION OF OZONE GENERATOR OPERATION / TREATED AIRSPACE
Model
RECOMMENDED OPERATION DURATION / TREATED
AIRSPACE (M3) IN "AUTO" MODE
P1
10 minute operation / 20
minute pause
AIRCLEAN 7G
<100
(5051)
AIRCLEAN
<140
10G (5050)
AIRCLEAN
<210
15G (5054)
AIRCLEAN
<280
20G (5053)
RECOMMENDED OPERATION DURATION / TREATED AIRSPACE
Model
50 m3
100 m3
AIRCLEAN 7G-
10 min
20 min
ECO 5055
AIRCLEAN
4 min
8 min
20G-ECO
(5052)
V SCOPE OF APPLICATION
Ozone generator produces ozone from surrounding air. Ozone treatment is very effective in removing
unpleasant smells, bacteria, viruses, fungi, mites etc.
The user is responsible for any damages resulting from a non-conform use of the device!
VI STRUCTURE OF THE MACHINE
•
AIRCLEAN 10G (5050) | AIRCLEAN 7G (5051) | AIRCLEAN 20G (5053) | AIRCLEAN 15G (5054)
12
AIR PURIFIER
5053
5054
5055
AIRCLEAN
AIRCLEAN
AIRCLEAN
20G
15G
7G-ECO
20000 mg/h
15000 mg/h
7000 mg/h
170 m3/h
170 m3/h
170 m3/h
118 mm, 4
118 mm, 4
135 mm, 4 W,
W, 254 nm
W, 254 nm
254 nm
205 W
160 W
98 W
230V~ / 50Hz
P2
P3
20 minute operation / 20
40 minute operation / 20
minute pause
minute pause
100~150
150~200
140~210
210~280
210~315
315~420
280~420
420~560
(M3)
150 m3
200 m3
300 m3
Terrible
air quality,
30 min
40 min
60 min
Operation
in "Hold"
12 min
15 min
25 min
mode
Rev. 26.04.2017
2
3
1
4
1 – air outlet
2 – control panel buttons:
On/Off – main on/off switch
Auto – auto mode operation
Timer – timer mode operation
Set – access to parameter setting mode
Up – increasing parameter values
Down – decreasing parameter values
3 – display
4 – remote control – description of buttons: same as control panel buttons
5 – filter
6 – fuse socket
•
AIRCLEAN 20G-ECO (5052) | AIRCLEAN 7G-ECO (5055)
1
1 – air outlet
2 – operation indicator lamp
3 – operation time selector knob
Rev. 26.04.2017
5
6
3
2
4
5
4 – fuse socket
5 – air filter
13