Télécharger Imprimer la page

EINHELL RT-CD 18/1 Li Mode D'emploi D'origine page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Anleitung_RT_CD_18_1_Li_SPK7.qxp:_
10. Charger indicator
Indicator status
Red LED
Green LED
On for approx.
On for approx.
1 s
1 s
Off
Flashing
Off
On
On
Flashing
Flashing
Off
On
Off
21.12.2011
8:53 Uhr
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack in quick charge mode.
The battery pack is fully charged (charging completed)
Action: Take the battery pack out of the charger. Disconnect the charger
from the mains supply.
Adapted charging
The charger is in gentle charging mode. For safety reasons the charging is
performed less quickly and takes more than 1 hour. The reasons can be:
- The battery pack has not been used for a very long time or an already flat
battery was further discharged (exhaustive discharge).
- The battery pack temperature is outside the ideal range (between 10° C
and 45° C).
Action: Wait for the charging to be completed; you can still continue to
charge the battery pack.
Fault
Charging is no longer possible. The battery pack is defective.
Action: Never charge a defective battery pack. Take the battery pack out of
the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold (below 0°
C).
Action: Remove the battery pack and keep it at room temperature (approx.
20° C) for one day.
Seite 17
GB
17

Publicité

loading

Ce manuel est également adapté pour:

45.132.69