Télécharger Imprimer la page

Technical Specification - Agilent Technologies TwisTorr 304 FS on board Controller Notice De Mode D'emploi

Publicité

17
Technical Information

Technical Specification

Technical Specification

Pwr supply (mains):
Protection fuse
Pwr supply (24 Vdc):
Protection fuse
Compliance with:
Power cable
Serial communication
(TwisTorr 304 kit)
Storage temperature
Input
Internal use only
Installation category
144/179
Technical Specification
Input voltage:
Input freq.:
Max input pwr:
Stand-by pwr:
Max oper. power:
Input voltage:
Max input pwr:
Stand-by pwr:
Max oper. power:
TwisTorr 304 FS on board Controller User Manual / 87-901-028-01 (A)
100 - 240 Vac
50 - 60 Hz
300 VA
10 W
150 W with water or air cooling
4 A
24 Vdc
200 W
10 W
150 W with water or air cooling
8 A
UNI EN 292-1
UNI EN 292-2
EN-CENELEC 55011
IEC 1000-4-2 (ex 801-2)
IEC 1000-4-3 (ex 801-3)
IEC 1000-4-4 (ex 801-4)
EN 61010-1 (IEC 1010-1)
EN 1012-2
With European or NEMA plug 3 meters long
(optional)
RS232 cable with a 9-pin D type male connector
and a 9-pin D type female connector, and TwisTorr
software (optional)
-20 ° C to +70 ° C
75 Vac, three phase, 1010 Hz
Max. altitude 2000 m
II

Publicité

loading

Ce manuel est également adapté pour:

X3507-64002X3507-64003