1. GENERAL CHARACTERISTICS
Application range
Rated crimping force
Minimum operating pressure
Dimensions (ref. to Fig. 7)
Weight with battery
Motor
Operating temperature
Recommended oil
Operating speed
Safety
Rechargeable battery
Type
Weight
Battery charger
Input
Acoustic noise
(1)
L
pA
L
pCPeak
L
WA
(2)
Vibration
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
= weighted continuous acoustic pressure level equivalent.
pA
L
= maximum value of the weighted acoustic displacement pressure at the work place.
pCPeak
L
= acoustic power level emitted by the machine.
WA
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2 Standard, and under
operating conditions much more severe than those normally found.
5
suitable for installing electrical compression connectors
on conductors up to 300 mm
kN
bar (psi)
mm (inches)
kg (lbs)
V
°C (°F)
twin speed operation and automatic switching from
a rapid advancing speed of the ram to a slower,
V / Ah / Wh
kg (lbs)
type
V / Hz
W
dB (A)
dB (C)
dB (A)
2
m/s
60
742 (10037)
300x350x83 (11.8x13.8x3.3)
4,5 (9.9)
18
-15 to +50 (+5 to +122)
ENI ARNICA ISO 32 or equivalents
more powerful crimping speed
maximum pressure valve
18 / 5.2 / 93.6
CB1852L (Li-Ion)
0,66 (1.45)
ASC55-EU
220 - 240 / 50 - 60
85
73
94.5
79
0.575 max.
2
(600 MCM)