The boiler carries out the startup stages in sequence according to the procedures defined by the parameters that manage levels and
times, reaching the work condition unless anomalies or alarms occur, according to the following table:
Status
OFF
START - PREHEAT
PELLET PRELOAD
AWAITING FLAME
PELLET LOADING
FIRE PRESENT
WORK
WORK MODULATE
BRAZIER CLEANING
FINAL CLEANING
Do not use flammable liquids to light the unit.
In case of persistent failed lighting, contact the Service Centre.
4.4 Work stage
After the 'STARTUP' stage, the boiler goes to the 'WORK' mode which is the normal operation mode.
The user can adjust the heating power from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
DHW circuit function activation ON is displayed by the segment/LED [A].
Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of pellets.
Make sure the unit is off when loading pellets.
The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
The bags of pellets must be kept at least 1.5 m from the boiler.