4) Pull the water line A out of cabinet from the front of unit as seen in Illustration
4.
5) To disconnect the electrical wires, push down on the locking tab of the plastic
connectors and gently pull the two ends apart.
6) Remove the top hinges (4 screws on each side) and lift off the doors. Remove
the middle hinges (3 screws) if necessary.
water line A
connector
water line B
screw B
electrical connector
How to Reconnect the Water Line
1) Reinstall the cabinet side tubing (Water Line A, Illustration3) to the connector
by firmly pushing the tubing into the union as far as it will go. Follow the color
mark on the tube, as seen in Illustration 1. Do not depress the end of the union
when inserting the tube. Replace the black locking clip.
2) Repeat at the back panel of the union (Water Line B), again making sure that
the tubing is inserted as far as it will go. Follow the color mark on the tube.
Replace the black locking clip.
Be careful not to bend or distort the tubing. Also check to ensure there are no
foreign objects in the connector, union, or tubes.
Refer to the owner's manual for instructions on removing the lower drawers.
Illustration 3
Illustration 4
water line cover
screw A
black locking clips
water line A
hinge screws