4.7 Combining multiple drivers
4.7.1 Master to Slave over Slave
Master unit
»90°« Output of
is
Slave unit 2
»IN« Input of
Unit 2, Output »90°«
Slave unit 4
the »IN« Input of unit 4 etc...
To establish a low overspill or high coverage system for very large areas:
- Connect the »90°« jack socket of the Master loop driver to the »IN« jack of the next loop
driver (Slave unit 2).
- Connect the »0°« jack socket of unit 2 to the »IN« jack of the next loop driver (unit 3).
- Connect the »90°« jack socket of unit 3 to the »IN« jack of the next loop driver (unit 4).
- Connect the »0°« jack socket of unit 4 to the »IN« jack of the next loop driver (unit 5).
- Repeat this sequence as needed
- Connect the respective phase-shifted loops to the »speakON« connectors on the ac-
cording drivers.
- Power all components up and adjust accordingly.
This allows you to install an inductive loop system in vast areas like exhibition halls and
stadiums.
32 English
is connected to...
is connected to...
is connected to
connected to
Slave unit 1
...
»IN« Input of unit 1, Output »0°«
Slave unit 3
»IN« Input of unit 3, Output »0°« is
of Unit 1...