Functional details
Insufficient quantity of electricity
KRÄNZLE 1050 TS T: 230 Volt / 50 Hz
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.
Electrical connection
The machine is supplied with a 5 meter electrical power cable with plug. The mains
plug must be fitted to a standard grounded socket with a 30mA residual current
operated device. The socket must be protected with a 16A fuse on the mains side.
When using an extension cable, this must have an earthed lead which is properly
connected to the socket. The conductors in the extension cable must have a
minimum cross section of 1.5 mm². Plug connections must be of a spray-proof de-
sign, and may not be located on a wet floor. With extension cables of more than 10
m the minimum cross section must be 2.5 mm! When using a cable drum, always
keep the cable wound as far as possible.
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline. Consequently
the motor of the high pressure cleaner does
not start or even blows.
The power supply may also be insufficient if
the power cable is too long or too thin.
If extension cables are too long, this may
lead to a voltage drop causing malfunctions
or start-up difficulties.