The control regulation necessary in order to obtain nominal calorific output is the following (see Cap. TECHNICAL DATA):
1A - PRIMARY air
PADOvA
C – OvEN light
The oven is equipped with a light, which turns on by pulling out slightly the lever C
To ignite the flame follow the instructions below (see Cap. IGNITION) :
Bring the flue gas control to the LIgHTINg UsE position (any butterfly valve placed on the flue gas exhaust pipe must also be opened).
Open the primary and secondary air control.
After having started the fire with small pieces of wood and waited until it is well lit.
Bring the flue gas control to the OvEN position.
Close any butterfly valve placed on the flue gas exhaust pipe must also be opened.
The control regulation during the LIgHTINg phase is the following :
PADOvA

TECHNICAL DATA

Definition in accordance with
Nominal power in kW
Efficiency in %
Assorbimento elettrico in W
smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly wood consumption in kg / h (wood with 20% humidity)
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
fire prevention safety distances
heatable m
(30 kcal/h x m
3
(*) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of proven efficiency.
(**) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
product is: favourable type of building (30 kcal/h x m
x m
).
3
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
The declared technical data have been achieved by burning beech wood class "A1" according to the requirement UNI EN ISO 17225-5 and wood
moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and some specific adjustments
on the appliance could be needed.
26
2A - sECONDARY air
CLOsED
1A - PRIMARY air
OPEN
O)
2
)
3
); less favourable type of building (40 kcal/h x m
3
TERTIARY air
1/2 OPEN
PRE-ADJUsTED
Picture
2A - sECONDARY air
OPEN
ENgLIsH
B - sMOkEs control
OvEN COOKING UsE function
6.
B - sMOkEs control
LIgHTINg UsE function
PADOvA
EN 12815
8
25
75
150
(*) 4 - 200 x 200 Ø 200
12 ( 1,2 mm H
O)
2
2,5
0,07 - 875 mg/m
3
10,5
270
210 x 175
226 x 270 x 384
310 x 286 x 410
Movable - flat
850-910
900
600
174
Chapter FIRE sAFETY
229 (**)
); unfavourable type of building (50 kcal/h
3