The device is equipped with registers of primary and secondary air.
A- PRIMARY air register
(Picture
With the primary air control is adjusted the passage of air through the ash drawer and the grate in the fuel direction. The primary air is
necessary for the combustion process. The ash drawer must be regularly emptied, so that the ash does not obstruct the primary air entry.
Through the primary air the fire is also kept alive.
During wood combustion, the register of primary air must be opened only for a while, because otherwise the wood burns fast and the stove
may overheat. For the correct arrangement (see chapter Normal operation).
B - sECONDARY air register
Over the door of the hearth there is the secondary air control.This regulator must be open (the lever must be moved to the right), especially
for wood combustion, so that un-burnt carbon does not undergo a post-combustion. See chapter Normal operation. Through this register
it is possible to adjust the power of the stove.
Leaving it slightly open, according to the flue of the chimney, it is possible to keep the glass clean.
The adjustment of the registers necessary to reach the rated calorific yield is the following one:
WANDA EVO
WANDA CLAssIC EVO
C - AIR REgIsTER for the heating of the environment
This register, through a fan controlled by a thermoregulator pos. D, adjusts the warm air output ONLY from the front side of the appliance.
D - FAN ELECTRIC THERMOCONTROLLER
UNIT OPERATION.
This electronic thermocontroller for packaged units manages ventilation air flows. The unit is switched on or off by pressing and holding the
1 button. During operation the display shows the set speed alternating with unit status, led 9.
When the unit is off, the display also remains off. The unit can be controlled MANUALLY or AUTOMATICALLY.
WARNINg: the correct operation of the unit is assured only for the proper motor for which it has been manufactured.
Improper use relieves the manufacturer from each responsibility.
MANUAL mode
To access MANUAL mode, press the 2 button; when the 3 light comes on the function
is active. The 4-5 buttons are used to select one of the five fan speeds, also active
when the flue is cold.
The motor is started in automatic mode by a mechanical thermostat (the display
shows WAIT), which is activated when the temperature is at least 45°C (fixed value,
not modifiable). The 6 led indicates that the thermostat contact is closed.
AUTOMATIC mode
To access AUTOMATIC mode, press the 2 button; when the 7 light comes on the
function is active. Use the 5 button to set the speed. The 4-5 buttons are used to
select one of the five fan speeds.
In automatic mode the COMFORT temperature can also be selected. Press the 4
button to access the COMFORT temperature setting and then set the value using
4-5. This setting allows the user to reduce fan noise when the room temperature measured by the probe inside the controller exceeds the
comfort set point; the motor operates one speed lower (this mode has no effect in first speed) and is signalled by the 8 led.
LANgUAgE menu.
Pressing and holding the 2 button accesses the LANgUAgE menu, where the display language can be changed using the 4-5 buttons (IT,
EN, DE, FR). Pressing the 2 button briefly again accesses the DIsPLAY menu, where the brightness can be adjusted (between 10 and 150).
Pressing the 2 button briefly another time accesses the DEgREEs menu, where the temperature display can be set as °C or °F.
BUZZER menu
Pressing the 2 button briefly a final time accesses the buzzer menu, where audible buzzer can be enabled or disabled.
REMOTE CONTROL OPERATION:
The electronic controller for packaged units can be managed by an IR remote control.
• The controller is switched on or off by pressing and holding the 11-12 buttons.
• To switch from MANUAL to AUTOMATIC on the IR remote control press the 13-14 buttons. The LED corresponding
to the operating mode comes on, manual 3 or automatic 7.
• In MANUAL mode only the buttons in the 11-13 group are enabled for selecting one of the five speeds.
• In AUTOMATIC mode, the buttons in the 12-14 group are enabled for selecting one of the five speeds, as well
as the buttons in the 11-13 group for changing the COMFORT set point.
The 10 LED comes on whenever a button is pressed on the remote control; if this does not happen, check the
batteries.
26
7)
(Picture
7)
Hourly consumption in kg/h
2,3
2,3
(Picture
(Picture 7 - Picture
PRIMARY air
10% Open
10% Open
7).
10).
5
6
7
7
8
ENgLIsH
sECONDARY air
TERTIARY AIR
75% Open
PRE - ADJUSTED
75% Open
PRE - ADJUSTED
3
7
9
8
A
2
4
5
A
1 2 3 4
11
O1
13
6
OK
1
10
12
14