Adjustment and Derating:
The Vega 750 series is designed to provide a max power of 750W at nominal output voltages. The following
procedure must be used to ensure the PSU is operated within its ratings:
Calculate user power for each module (volts x amps)
Add all individual module powers together. The total power must not exceed the value given
Calculate secondary transformer turns x amps for each module. See the outputs table for transformer
secondary turns
Add all modules turns x amps together and this must not exceed amperturns
If necessary reduce the loading untill the conditions are met, ie. power and ampere - turns maxima
Mechanical Outline Drawings:
Primary Options
Specified Option
Inhibit
Enable
Logic 0 = 0-0.8V
Secondary Options
Pin 5 Logic 0
Outputs OFF
Outputs ON
Logic 1 = 2-5V
Pin 6 Logic 1
Outputs OFF
Outputs ON
with respect to 0V (Pin 3)