1-2. ZWD150PAF/J
L: AC Input terminal (pin 1 of CN1)
Live line (fuse in line)
N: AC input terminal (pin 3 of CN1)
Neutral line
FG: Input terminal FG (pin 5 of CN1)
Safety earth (Frame Ground)
Connect to safety ground of apparatus
or equipment.
PE: Protective Earth (Connected to pin 5
of CN1)
Must be connected to electrically safety
ground of apparatus or equipment by
electrically conductive spacers. The
mounting surface of the spacer should be
within MAX f8mm.
V1: CH1 +ve Output terminal
G1: CH1 –ve Output terminal
V2: CH2 +ve Output terminal
G2: CH2 –ve Output terminal
V.ADJ: 5V Output Voltage adjust trimmer (VR1)
The 5V Output voltage rises when the trimmer is
turned clockwise.
V.ADJ : 24V Output Voltage adjust trimmer (VR2)
The 24V Output voltage rises when the trimmer is
turned clockwise.
-R : CN3 ON/OFF control -R terminal
+R : CN3 ON/OFF control +R terminal
*Input & Output connector ( J.S.T )
(also for option model /JL,/JA)
Connector
Input (CN1)
B3P5-VH
Output (CN2)
*Output Current of each connector pin must be less than 5A.
(7A at peak load)
*Hand Crimping Tool : YC-160R ( J.S.T )
*Connector for Remote ON/OFF control: CN3 (J.S.T)
Connector
B2B - XH - A
*CN3 is normally shorted by JM-2W-96 ( J.S.T )
*Hand Crimping Tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
- 2 -
TDK-Lambda
ZWD150PAF Series
INSTRUCTION MANUAL
Recommended
Housing
VHR-5N
SVH-21T-P1.1
B8P-VH
VHR-8N
SVH-21T-P1.1
Recommended
Housing
Terminal Pin
BXH - 001T - P0.6
XHP - 2
or SXH – 001T - P0.6
Terminal Pin