Configuration and Function of CN61 is shown as below.
CN61
3. Terminal Connection Method
Pay attention to the input wiring. If it is connected to wrong terminal, the power supply may be damaged.
Input must be off when making connections.
Connect
terminal of mounting hole to protective earth of the equipment.
The output load line and input line shall be separated to improve noise sensitivity.
Do not apply stress to PCB, when connecting or removing connectors.
Do not apply stress to the components ( especially VR51 ) when connecting or removing connectors.
Remote ON/OFF control lines shall be twisted or used shielded wires. Separate from load line.
Use input/output connector (housing) specified by the table below.
Housing, Terminal Pin and Tool are not included with this product. (Refer to the following)
Input/Output/Standby
Input
CUS200M
( CN1 )
Output
CUS200M
( CN51 )
Standby
CUS200M
( CN61 )
Hand Crimping Tool : YC160R,YC-930R,YC-610R (J.S.T.)
4.Explanation of Function and Precautions
4-1. Input Voltage Range
Input voltage range is single phase 85-265VAC(47-63Hz). Input voltage, which is out of specification, might lead unit damage. For cases
where conformance to various safeties required, described as 100-240VAC (50-60Hz). If input voltage is less than 115VAC, output power
need to be derated.
Derating curve for standard CUS200M
Pin No.
1
2
3
4
5
6
7
8
Connector & Housing & Terminal Pin
Model
Connector
B3P5-VH(LF)(SN)
B6P-VH(LF)(SN)
B8B-PHDSS(LF)(SN)
Function
STBY+: Standby power + (5V+).
STBY-: Standby power - (5V-).
No connection.
No connection.
No connection.
DC_OK: Please refer to 4-12.
R+: Remote ON/OFF terminal +. Please refer to 4-13.
R-: Remote ON/OFF terminal -. Please refer to 4-13.
Housing
VHR-5N
SVH-21T-P1.1
VHR-6N
SVH-41T-P1.1
PHDR-08VS
SPHD-001T-P0.5
INPUT VOLTAGE
(VAC)
85
115~265
- 3 -
TDK-Lambda
CUS200M
Instruction Manual
Terminal Pin
Maker
J.S.T.
MOUNTING A,B,C,D,E
LOAD (%)
80
100