1.Model name identification method
CUS 200M – 12 □
Option
blank
/L
/A
2.Terminal Explanation
① Mounting hole (hole diameter : φ3.5mm), This hole is not connected to Protective Earth of CN1.
② L : AC Input terminal Live line (Fuse in line.).
③ N : AC Input terminal Neutral line (Fuse in line.).
④
: Earth terminal.
⑤ Mounting hole (hole diameter : φ3.5mm), This hole is connected to Protective Earth of CN1. The mounting surface of the spacer should be
within Maxφ7mm.
⑥ Same as mounting hole
⑦ V-: Output Terminal -.
⑧ V+: Output Terminal +.
⑨ LED hole: Output monitoring indicator (Green color).
⑩ V.ADJ : Output voltage adjust trimmer. The output voltage rises when the trimmer is turned clockwise.
⑪ Same as mounting hole
Description
Standard model.
With chassis model.
With chassis and cover model.
○
5 .
○
1 .
Option
Rated Output Voltage
Output Power (actual output power refer to the specification)
Series Name
- 2 -
TDK-Lambda
CUS200M