Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder with a fitting screwdriver from the housing (anti-clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Number of DMX channels:
DMX-512 connection:
Sound-control:
Maximum ambient temperature T
Maximum housing temperature T
Min.distance from flammable surfaces:
Min.distance to lighted object:
Number/LEDs:
LED beam angle:
Color temperature:
Fuse:
Dimensions (LxWxH):
Weight:
Accessories:
EUROLITE TH-50H theatre-hook for 50mm pipe
EUROLITE TH-90 theatre-hook for 50mm pipe
EUROLITE TH-100 theatre-hook max. 200kg
EUROLITE TH-200 theatre-hook max. 200kg
Safety-rope 400x3mm up to 10kg
Safety-rope 900x3mm up to 10kg
Safety-rope 1400x3mm up to 10kg
Please note: Every information is subject to change without prior notice. 30.06.2009 ©
:
a
:
B
51913650
51913655
230 V AC, 50 Hz ~
max. 50 W
2
3-pin XLR
via built-in microphone
45° C
55° C
0.50 m
0.10 m
24
25°
3200 K
6000 K
T 0.5 A, 250 V
265 x 265 x 290 mm
5.5 kg
No.
58000653
58000720
58000730
58000740
58010120
58010130
58010135
21/40
00029373.DOC, Version 1.1