J: TIMER SET button
(OFF Timer)
(OFF Cycle Timer)
(ON Timer)
K: Time setting buttons
L: SET button
M: CL button
N: VENTILATION button
O: Remote control sensor
P: ACL button (ALL CLEAR)
Q: Slide switch
Parts Name and Functions (continued)
Indicator when swing operation is stopped
Fan and heating
During cooling and drying, the flap does not stop at the downward position.
Even if the flap is stopped at the downward position during the swing
operation, it does not stop until it moves to the third position from the top.
Use this button while the unit is operating to switch between timer settings.
:
The air conditioner stops after a preset time elapses.
:The air conditioner always stops after a preset time elapses.
:
The air conditioner starts after a preset time elapses.
: Press this button to increase the time.
: Press this button to decrease the time.
Use this button to set the timer.
Use this button to clear the timer setting.
This is used when a ventilation fan (available commercially) is connected.
Pressing the VENTILATION button turns the fan on and off. The ventilation
fan also turns on and off when the air conditioner unit is turned on and off.
(The display of the remote control unit shows "
is running.)
* If the VENTILATION button is held down for 4 or more seconds when the
batteries have been replaced, "
ventilation fan can be used.
This detects the temperature around the remote control unit when the
remote control unit position has been selected using the sensor button.
Puts the wireless remote control unit into pre-operation status. This is used
after the batteries have been replaced or when the slide switch setting has
been changed.
This switch is for setting the operation mode of the indoor unit and setting the
flaps.
NOTE
•
The wireless remote control unit sends the temperature signal to the air
conditioner regularly at five-minute intervals. If the signal from the
wireless remote control unit stops for more than ten minutes due to the
loss of the wireless remote control unit or other trouble, the air conditioner
will switch to the temperature sensor which is built into the indoor unit and
control the room temperature. In these cases, the temperature around the
wireless remote control unit may differ from the temperature detected at
the air conditioner's position.
•
When low fan speed is selected and the air conditioner is in cooling
operation at a low outdoor temperature of less than 10°C, the air
conditioner may automatically switch to medium fan speed to prevent
freezing.
Cooling and drying
" while the ventilation fan
" appears on the display, and the
7