Maintenance
To service the cartridges
Entretien des cartouches
Shut off the main water supply, then remove all
the
components from (6) to (19). (See Fig.6). After-
wards, shut off the 2 check valves (1) by turning
them clockwise with a screwdriver. Unscrew the
screw (3), the large nut (4) and remove the car-
tridges (2 & 5).
To clean the cartridges (thermostat only), you
may need to soak it in a vinegar and water so-
lution to remove lime build-up. If replacement is
necessary, insert the new cartridges and screw
the large nut (4), the screw (3) back on. DO NOT
OVERTIGHTEN.
To reinstall the components, reverse the above
steps.
Fermer l'alimentation d'eau principale et dé-
monter
toutes les composants de (6) à (19) (Voir Fig.6).
Ensuite, fermer les deux valves d'arrêt (1) en les
vissant dans le sens des aiguilles d'une montre.
Dévisser la vis (3), le manchon de valve (4) et en-
lever les cartouches (2 & 5).
Pour nettoyer les cartouches (thermostat seule-
ment), plongez les dans une solution d'eau et de
vinaigre. Si nécessaire, insérer les nouvelles car-
touches revisser les manchons des valves (2 &
5) et la vis (3). NE PAS TROP SERRER !
Pour remonter tous les composants, inverser les
étapes ci-haut.