Product HANDBOOK
Connector version
KPSB6 –J
Input Parameters:
Standard
Nominal input voltage
Input voltage range
Input frequency range
Maximum input current 100% load, Vin 100VAC
Inrush current (cold start, 25°C)
Class of Equipment
Overvoltage Category
Output Parameters:
Model number
KPSB6-3R3
KPSB6-5
KPSB6-9
KPSB6-12
KPSB6-15
KPSB6-24
All outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if
the total output voltage exceeds 60Vdc
If the total voltage of outputs connected in series exceed the 60Vdc SELV limit then all outputs must be
considered non-SELV.
Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to
service engineers making inadvertent contact with the output terminals in the end equipment.
Cooling for unit:
The KPSB series is convection cooled, the recommended installation is as follows
Equipment top
Page 14 of 15
KPSB6 Series
Vout (V)
Output
current (A)
3.3
1.5
5
1.2
9
0.67
12
0.5
15
0.4
24
0.25
KPSB6
90A max at 240VAC
KPSB6-E
KPS6 Series, 260674 issue 2, Oct 2020
62368-1
100-240 VAC
90 – 264VAC
47 – 63Hz
0.25A
II
II
KPSB6-J

Publicité