Product HANDBOOK
KPSB6 Series
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA62368-1 (<60Vdc or 42.4V peak), when connected in series, combinations of these outputs
may exceed these values and become hazardous output voltages. See output parameter section.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Environmental Specifications:
Description
Operation
Storage
KPSB6
Use
Indoor
-
Temperature
-40°C to +80°C
-40°C to +85°C
(derating see note 1.)
Humidity
10 - 93% RH, non-condensing
10 - 93% RH, non-condensing
Altitude
5000m
5000m
Orientation
See Figure 1
Material Group
IIIb
Pollution Degree
2
Note 1.
For KPSB6 derate linearly from 60°C to 80°C.
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuits to secondary: 3kVAC, 4142VDC 1 minute,
Safety Certifications:
nd
UL / cUL 62368-1 (2
Edition)
nd
IEC / EN 62368-1(2
Edition)
CE marking when applied to any KPSB6-yy product indicates compliance with the Low Voltage Directive in
that it complies with EN62368-1 and the RoHS Directive.
Fusing: Internal fuses (F1): Single fuse in the L line, T1A, 250V,
Input Connection:
ACN – Neutral ACL – Live
Pinned version
KPSB6 –xx
Encapsulated version
KPSB6 – E
Page 13 of 15
KPS6 Series, 260674 issue 2, Oct 2020