Table of burner and nozzle specifications

Table 1
Burner
Diameter
(mm)
Rapid (Large)
100
(R)
Semi-rapid
75
(Medium) (S)
Auxiliary
51
(Small) (A)
Supply
pressure
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
Ø180
S
A
R
K3M1S/FR
KN3M1S/FR
WARNING! The glass lid can
WARNING! The glass lid can
WARNING! The glass lid can
WARNING! The glass lid can
WARNING! The glass lid can
break in if it is heated up.
break in if it is heated up.
break in if it is heated up.
break in if it is heated up.
break in if it is heated up.
Turn off all the burners and
Turn off all the burners and
Turn off all the burners and
Turn off all the burners and
Turn off all the burners and
the electric plates before
the electric plates before
the electric plates before
the electric plates before
the electric plates before
closing the lid.
closing the lid.
closing the lid.
closing the lid.
closing the lid.
Thermal power
Bypass
kW (p.c.s.*)
Nominal
Reduced
3.00
0.70
1.90
0.40
1.00
0.40
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
Liquid gas
Nozzle
Capacity*
1/100
1/100
g/h
(mm)
(mm)
***
41
87
218
30
70
138
30
52
73
28-30
20
35
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Burners
Voltage and
frequency
Electric Hotplate
ENERGY LABEL
Natural gas
Nozzle
Capacity*
1/100
l/h
(mm)
**
G20
G25
214
128
286
332
136
104
181
210
71
76
95
111
20
37
17
25
25
45
34x39x44 cm
58 l
width 42 cm
depth 44 cm
height 18 cm
may be adapted for use with any
type of gas shown on the data plate
see data plate
Rapid Ø 180 mm: 2000 W
Directive 2002/40/EC on the label
of electric ovens.
Regulation EN 50304
Declared energy consumption for
Natural convection Class –
heating mode
Static
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas)
1275/2008 (Stand-by/ Off mode)