Checking the seals
This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre.
When thoroughly cleaning the stove, the authorised technician must check that the gaskets of
- port
- ash drawer
- hatches
are intact. If not, they will have to be replaced.
Smoke conduit cleaning
This operation must be carried out by a Ravelli Assistance Centre. Schedule this type of cleaning with the Ravelli Assistance
Centre.
The stove is equipped with some hatches for cleaning the internal smoke ducts.
To clean the smoke ducts, proceed as described below:
step
action
1
Remove claddings.
2
Open the hatches.
3
Clean the ashes, eventually use a brush or similar and reassemble everything.
Note: the hatches are equipped with gaskets, therefore, before reassembling them, make sure that the gaskets are not
worn.
Note: The operation must be carried out when the stove is cold, using an ash vacuum cleaner.
1
Use and maintenance manual Vittoria Déco
x4
x4
Rev.1 10/03/2021
Pag.51