Télécharger Imprimer la page

DeWalt DXCMH1608WB Guide D'utilisation page 23

Publicité

Les langues disponibles

Les langues disponibles

CoDe
PossIBle CAuse
16
Loose pulley
17
Loose flywheel
18
Carbon build-up in pump
19
Belt to tight
20
Pulley misalignment
21
Air tank pressure is too high
22
Engine problem
23
Engine or pump oil is low
24
It is normal for some pressure drop to occur
25
Damaged regulator
26
Detergent type oil being used in pump
27
Extremely light duty cycles
28
Piston rings damaged or worn
PossIBle solutIon
Tighten pulley set screw, torque to 145–180 in.-lbs. (16.4– 20.3 Nm).
Tighten flywheel screw, torque to 22–26 ft.-lbs. (29.8–35.3 Nm).
Contact a D
e
WALT factory service center or a D
service center.
Check belt tension, see Adjusting Belt tension under
Maintenance.
See Motor Pulley/flywheel Alignment under Maintenance.
Open the regulator and reduce air tank pressure to less than
40 psi.
Contact a D
e
WALT factory service center or a D
service center.
Add D
e
WALT synthetic compressor oil to pump. See Compressor
Pump oil under Maintenance.
If there is an excessive amount of pressure drop when the
accessory is used, adjust the regulator as instructed in regulator
under Features.
note: Adjust the regulated pressure under flow conditions while
accessory is being used.
Replace.
Drain oil and refill pump with D
e
Run unit for longer duty cycles. It is recommended to run at high
throttle 50-75% of the run time and idle for 25% of the run time.
Contact a D
e
WALT factory service center or a D
service center.
23
e
WALT authorized
e
WALT authorized
WALT synthetic compressor oil.
e
WALT authorized

Publicité