_900_serie.book Seite 38 Mittwoch, 22. März 2006 4:28 16
Installation
Settings for charging voltage for 925-024TB, 925-024TC, 915-024TB, 915-
024TC and 908-024TA:
Charging
voltage
27,6 V
28,8 V
29,6 V
Settings for the limitation of the period of the main charging phase:
Time limitation of
the main charging
phase
4 hrs.
8 hrs.
No timer function
Mute function
If the mute function is switched on, then the unit is operated without active
cooler. Thereby the noise development decreases and the charging capacity
is reduced.
➤ Switch the mute function of the unit ON and OFF with the switch at the
front (see figure 1-9, pos. 1, page 3-5).
5.2
Connecting the IU0U automatic charger
Battery
Warning!
Absolutely avoid contact with the battery fluid!
Caution!
Batteries with cell connection may not be charged, since explosive
gases could occur by overheating the battery.
38
Switch 1
Switch 2
OFF
OFF
ON
OFF
OFF
ON
Switch 3
Switch 4
OFF
ON
ON
OFF
OFF
OFF
IU0U automatic charger
Application range
Old starter batteries,
mains charger operation
Wet and gel batteries
Fleece batteries
Application range
Wet batteries
Gel and fleece batteries
-