Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
TEC30D EV
Fault
Cause
The generated
Load is over 2.5 kW.
voltage is not
Air filter is dirty.
constant.
Inverter is damaged.
Power cable is disconnected or
damaged.
Malfunction in the pump power
supply.
Injectors are dirty or faulty.
The battery
Battery charger fuse is blown.
charger does not
supply voltage.
12

Warranty

The statutory warranty period applies. If the product is defective, please
contact the service partner in your country (addresses on the back on the
instruction manual).
Our experts will be happy to help you and will discuss the warranty process
with you in more detail.
13

Disposal

➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the product, ask your local recycling
M
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
Protect the environment!
B
Do not dispose of any batteries with general household waste.
Return defective or used batteries to your retailer or dispose of
them at collection points.
EN
Remedy
➤ Reduce the consumers.
➤ Clean the air filter (chapter
"Servicing the air filter" on
page 25).
➤ Contact an authorised work-
shop.
➤ Replace the fuse.
Warranty
27

Publicité

Table des Matières
loading

Table des Matières