TEC30D EV
10.2
Preparing maintenance work
!
CAUTION!
Note the following for all maintenance work:
The generator must not be running.
All the parts must be cooled down.
➤ Open the generator cover (fig. 4 2, page 4).
➤ Switch the generator to no function with the main switch (fig. 4 1,
page 4).
10.3
Finishing maintenance work
➤ Switch the generator to standby with the main switch (fig. 4 1, page 4).
➤ Close the generator cover (fig. 4 2, page 4).
10.4
Changing the oil
!
CAUTION!
Hot oil can cause burns. Use protective gloves.
A
NOTICE!
Only dispose of used oil at a specialist recycling station and
observe the local laws for environmental protection.
Do not mix oils with different characteristics or from different
manufacturers.
You may use the following oil:
Oil with the specifications:
– CCMC D4, D5, PD
– API CD, CE, CF, CG
– SHPD
SAE grade oils:
– 5W-30
– 5W-40
– 100W
– 100W-30 (recommended)
– 10W-30
– 15W-30
– 30
– 40
EN
Servicing the generator
23