The drive opens in the time set and intermediate movement with remote operation are possible, closure with automatic closing feature.
CP (24)
First opening with a pulse no intermediate movement, model with light barrier, closure with automatic closing facility
Timer 2 channel
CP (24)
The drive opens at the time set, intermediate movements are not possible (program channel 1 + 2 simultaneously), closing with the automatic closing feature
Programme the timer in accordance with the programming instructions!
7.4. Programming
In order that you can adapt the gate system to your specific needs, the controller provides certain features and parameters that can be
enabled or disabled or adjusted. The following scheme illustrates how you can reach the desired menu items by way of a navigational aid.
The highlighted values indicate the default factory settings.
7.4.1.
Options
Press P3 once – open the menu for configuring "Options"
Press P2 once – choose the menu for configuring "Options"
Sub-menu options
- change the settings with "PROG/OK"
- move with P1 or P3 up and down in the menu
CMN
CMN
TA