3.2.a Altering PARAMETERS "P"
From within "Pro" settings, press the START "ST"
button; the message "P1" will be displayed
To confirm parameters in sequence "P" (P1 - P2 - P3 -
P4) press the "ST" button.
Now press the "SD" or CYCLE button to decrease and/or
the "SI" button to increase the parameter status (0-1).
(See table STANDARD SETTINGS PARAMETERS "P")
To exit settings, simply refrain from pressing any
buttons for at least 10 sec.
STANDARD SETTING PARAMETERS "P"
PARAMETER
FUNCTION 0
P1
Filling hot water
(40÷50°C)
P2
Normal washing
P3
Alternating heating
*
(first boiler than tank)
P4
1 wash pump
P5
Wait for boiler to heat
NOT ACTIVE
P6
Cycle START tank temp. Cycle START tank temp.
reached (preset)
NOT ACTIVE
P7
With P1=1: filling and heating of water in the tank is
carried out alternately, with pre-heated water from the
boiler, until the water level in the tank is reached.
*With P3=1: check fuse value of the safety
upstream of the machine (A).
3.2.b Altering PARAMETERS "T" and "L"
Press START "ST" to view programmed temperature.
The message "t1" will appear on the display,
indicating the temperature set for the water in the
tank (for the selected cycle).
Now press the "SD" or CYCLE button to decrease and/
or the "SI" button to increase the temperature/time
settings.
(See table STANDARD SETTINGS PARAMETERS
"T" and "L")
To confirm parameters and move on to the
following settings (in sequence L1 - L2 - L3 - L4 -
L5) press the "ST" button again.
To exit settings, simply refrain from pressing any
buttons for at least 10 sec.
38
FUNCTION 1
PRESET
STATUS
Filling cold water
0
with Pre-rinse
0
Simultaneous
0
heating (tank & boiler)
Not used
0
Wait for boiler to heat
1
ACTIVE
0
reached (preset)
ACTIVE
Not used
0
IMPORTANT
LC1 LC2 LC3 LC4
Part 3: For the technician
STANDARD SETTING PARAMETERS "T" and "L"
CAP 10-SO 100E
PARAMETER
FUNCTION
T1
Tank temperature
T2
Boiler entry temperat.
L1
Wash time
L2
Pause time
L3
Rinse time
L4
-
L5
-
CAP 12-SO 120E
PARAMETER
FUNCTION
T1
Tank temperature
T2
Boiler entry temperat.
L1
Wash time
L2
Pause time
L3
Rinse time
L4
-
L5
-
3.2.c STANDARD Parameter Settings
With the machine switched off, press the "SI" button for
10 sec.; all parameters (
as in the tables.
The message "PSt" will appear on the display,
confirming that the settings have been
programmed.
.
DYSPLAY ALARMS and
SIGNALS : SELF-DIAGNOSIS
when more than one alarm is detected simultaneously,
the relative codes will appear on the display in the
following order of priority:
1. H1-H2-H3
2. A1-A2-A3-A4-A5
3. F1-F2
The alarm and active function codes shown on the
display when the machine is in operation are:
- A1: FAILURE TO COMPLETE CYCLE
This alarm message appears when the machine
is switched back on after being switched off
using "IL".
-
A2
: BOILER OVERHEATING
This alarm message appears when the temperature
in the boiler exceeds 105
(the cycle underway will be completed).
SHORT MEDIUM LONG
INTENSIVE
CYCLE CYCLE
CYCLE
CYCLE
LC1
LC2
LC3
LC4
55°C
55°C
55°C
55°C
85°C
85°C
85°C
85°C
42 sec. 77 sec. 127 sec.
457 sec.
5 sec.
5 sec.
5 sec.
5 sec.
18 sec.
18 sec.
18 sec.
18 sec.
-
-
-
-
-
-
-
-
SHORT MEDIUM LONG
INTENSIVE
CYCLE CYCLE
CYCLE
CYCLE
LC1
LC2
LC3
LC4
55°C
55°C
55°C
55°C
85°C
85°C
85°C
85°C
42 sec. 77 sec. 127 sec.
457 sec.
5 sec.
5 sec.
5 sec.
5 sec.
18 sec.
18 sec.
18 sec.
18 sec.
-
-
-
-
-
-
-
-
P-T-L
) are automatically set
°
C;