It is recommended to make the heater works for the entire duration of the
pellet combustion.
The suggested pellet quantity is roughly calculated because the heater filled
with a few quantity of pellet produces an higher flame because there is more
air inside the burner, but the duration will be shorter. On the contrary if the
heater is filled with a big quantity of pellet the duration will be longer but the
flame will be lower because of the minor quantity of air inside the burner.
When the flame finishes the heater keep on heating for at least 2 hours
depending on the initial quantity of pellet which continues to heat also there
isn't open flame.
The heater can be filled again opening the drawer under the burner, according
to the instructions at the following points from 7 to 12 (unload and cleaning
operations) and then following the instructions at the previous points from 3
to 6 (loading and firing up) for refuelling the burner with additional pellet.
Once the heater is on, it will work with a pyrolysis process which consists in
the top-down anaerobic combustion of the pellet. This process will transform
the combusted pellet in a completely natural compound, that will be easy to
dispose of. Anyway, pay attention to the rules in force in your country about
the separate collection.
Unloading:
1. Open the door of the base and extract the burner.
2. Wearing the appropriated fireproof mitts, remove the top of the ash
drawer.
3. Keep wearing the fireproof mitts, you have to operate the opening of the
part underneath the burner so you can drop the combustion residues
inside the ash drawer.
4. Clean the inside of the brazier, using the poker if necessary, removing any
residual pellets even if still burning..
5. Please check that the edges and the lower door are clean so to have a
perfect closing. Then close it.
6. Close the drawer with its cover.
WARNING: The ash drawer has to be emptied only when the combustion
residues inside will be completely cold and off. For the disposal you have to
respect the rules in force in your country about the separate collection.
Reload
When you have executed the operations until the previous point 6, the
heater is ready to be used again. You have only to repeat the load procedure
restarted from the point 3 of the "LOADING AND FIRING UP" instructions.