3
Technical data
General data and operating conditions
Conformity
Approvals
DC supply voltage
Climatic conditions
Temperature range
Power derating
Vibration resistance
Permissible mounting
positions
Insulation voltage to PE
Enclosure
Digital inputs X4
Digital outputs X3
Dimensions
Height
Width
Depth
EDK10201EZ3 DE/EN/FR 5.1
Technical data
General data and operating conditions
CE
UL 508C
Voltage
Current
Class 3K3 to EN 50178
(without condensation, average relative humidity 85 %)
Transport
storage
Operation
of output currents for t
Resistant to acceleration up to 0.7 g
in the Drive PLC on a plug−in−station for extension board
50 V AC
IP 20
Level
Input current
Level
Load capacity
145 mm (incl. terminal strips)
72 mm
35 mm
Low−Voltage Directive (2006/95/EC)
Underwriter Laboratories (File−No. E132659)
Power Conversion Equipment
external +18 VDC −0 % ... +30 VDC +0 %
max. 8 A
(at max. load of all outputs)
−25 °C ... +70 °C
−25 °C ... +60 °C
0 °C ... +40 °C without power derating
+40 °C ... +55 °C with power derating
> +40 °C: 2.5 %/K
a
LOW (0 V ... +4 V)
HIGH (+13 V ... +30 V)
8 mA at 24 V
LOW (0 V ... +4 V)
HIGH (+13 V ... +30 V)
Output 05 ... 08: max. 1 A per output
Output 09, 010: max. 2 A per output