Charging phases

6V Low: slow charging
Once the battery has reached a voltage of 7.45 V the battery is fully charged. the
charger will then switch to maintenance charging at 220 mA.
12 V Low: slow charging
Once the battery has reached a voltage of 14.4 V the battery is fully charged. the
charger will then switch to maintenance charging at 70 mA.
12 V high: quick charging
Once the battery has reached a voltage between 14.5 V and 14.7 V the battery is
fully charged. As soon as the voltage drops to 13.7 V maintenance charging will
start.

End charging process

1. unplug from the Ac outlet.
2. Disconnect the charging clamp (black) from the vehicle's body, in exceptions
from the negative battery terminal (marked n or -).
3. Disconnect the positive charging clamp (red) from the positive battery terminal
(marked P or +).