Simpool pH model
Programmable digital peristaltic pump
User Menu
The User Menu allows to set the main pump dosing parameters.
You can browse through the User Menu with the F key and display:
PrI: allows to prime the pump without using the switch. You can start or stop the priming with the Enter
key. The display shows a flashing "PrI" and the pump starts running run at top speed.
SEt: allows to set the setpoint value from 5.00 to 9.00;
doS: allows to select the pump's operating mode, Alkaline AL.d or Acid ACI;
CAL: allows to access the Calibration Menu of the pH probe;
°C: allows to set the temperature value, from 0.0°C to 99.9°C;
OFA: allows to select the OFA alarms' control time frame within a range of 300 to 999 seconds or disable it
(OFF);
The parameters can be changed and the pH probe can be calibrated only if they have been enabled from the
Settings Menu, that is if:
 OnS (on-line Setpoint change) enabled
 Ond (on-line operating mode) enabled
 OnC(on-line probe calibration execution) enabled
 Ont (on-line manual temperature change) enabled
 OnA (on-line OFA alarm change) enabled
From the User Menu you can go back to the Initial Menu by pressing the F key for 3 seconds.
Programming Menu
The Programming Menu allows to set all of the pump's operating parameters and can be accessed only by entering
the password.
You can enter the Programming Menu only from the Initial Menu: after pressing Enter for 3 seconds, the display
shows "PAS", the LED turns orange and is steady. Then press Enter again and on the password selection menu
the first digit of "000" starts flashing. With the ▲ and ▼ keys you can increase/decrease the value displayed, with
Enter you can scroll and select the desired digit. After setting the correct password, press Enter again for 3
seconds.
From every menu you will go back to the first entry of the Initial Menu if no operation is carried out for more than 2
minutes.

3.2 QUICK START-UP

This section features the steps to carry out to use the pump straight away. For further details on operation, refer to
section 3.3 "Advanced Programming".
Here below are the main parameters to set in order to operate the pump:
From the User Menu you can proceed quickly with the steps below:
Prime the pump;
Select the Setpoint;
Set the pH Operating Mode;
Calibrate the pH measuring probe; (see pH Probe Calibration Menu)
Set the temperature (if in manual mode);
Select the time in seconds to control the PFA alarm;
Here below are the pump's default parameters:
pH Proportional Band equal to 1.5;
pH Cycle Period equal to 300 sec;
On-line modification of the User Menu values and On-line execution of the probe calibration enabled;
Stabilization Time: 10 sec;
OFA alarm disabled (OFF);
ADSP7000407
pH setpoint – pH Operating Mode –pH Proportional Band
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
27/03/2015
ENGLISH