Télécharger Imprimer la page

Fulbat Fulload 1000 Mode D'emploi page 4

Masquer les pouces Voir aussi pour Fulload 1000:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

- Switch OFF and Remove the AC Power Socket from the outlet.
- Remove the Black lead and then the Red lead.
- Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
• If the Battery is in the vehicle.
- Switch OFF and Remove the AC Power Socket from the outlet.
- Remove the lead from the vehicle chassis.
- Remove the lead from the battery.
- Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
THE CHARGING PROCESS
The charging stages are as follows:
Bulk Charge: charges using a constant maximum
current (1A) until the battery reaches 7.2V (6 Volt
Batteries) or 14.4V (12 Volt Batteries) - (LED Color
- Yellow).
Fully / Float: battery is fully charged and is being
maintained. (LED Color - GREEN).
LED STATUS INIDICATOR TABLE
A.C. Power connected,
battery disconnected
Bulk Charging
Level 1 Charging
Level 2,3 Charging
Battery Reverse polarity
connection
A.C. Power OFF
CHARGING CURVE (VOLTAGE)
FULLOAD 1000 - 3 STAGES
Tension
(V)
Courant
(A)
MAIN CHARGE
FULBAT - www.fulbat.com
Power Charging
Full
Red
Yellow
Green
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
MAINTENANCE
PULSE
Types of
Indication
Problems
Charger
No Indicator
does not
lights ON
work?
Charger
Fault LED
has no DC
is ON
output?
No Charging
Fault LED
Current?
is ON
Long char-
ging time,
Fault LED
Full light
is ON
does not
come on?
Fault
Red
OFF
OFF
The charger is maintenance free. If the power cord is damaged, the
charger must be left to the reseller for maintenance. The case should
OFF
be cleaned occasionally. The charger should be disconnected from the
OFF
power while cleaning.
ON
OFF
4
TROUBLE SHOOTING
Possible
Suggested Solution
Causes
-
Check AC connections and
-
No AC power
make sure Power Point is
switched ON
-
Check DC connection between
-
Output
charger and battery and
is short
make sure they are not short
circuited
circuiting
-
-
Reverse
Check that the crocodile clips
polarity
haven't fallen off the battery
-
connection
Check that the crocodile clips
to Battery
/ ring terminals are connec-
ted to the correct polarity
-
Battery is
severely
-
Check the Battery condition,
sulphated
age etc
-
Battery has
-
Battery may need
a damaged
replacement
cell
-
Move battery & Charger to
-
Overheat
cooler environment
protection
mode
-
-
Battery
Check the charger specifi-
capacity too
cation matches the battery
large
capacity
-
-
Battery is
Battery cannot be charged
defective
and must be replaced
MAINTENANCE

Publicité

loading

Produits Connexes pour Fulbat Fulload 1000