Operation
1. Reset at first start-up
A reset is required the first time the desk is used
before the desk can be used in the normal man-
ner. All desk columns are set to the same height
at the desk's middle position.
2. Reset
To perform a reset, you have to first deactivate
the energy-saving mode of the control unit by
briefly pressing the UP or DOWN button. Then
press and hold the UP and DOWN buttons simul-
taneously. The reset action will begin after 3 sec-
onds (at half speed). You can release the buttons
once the control unit makes two clicking sounds
to indicate the reset position has been reached.
The collision protection is not active during all
reset processes. Please be aware of potential
crushing hazards!
3. Factory settings (with UP/DOWN button)
To reset the desk to its factory settings, you
have to first deactivate the energy-saving mode
on the control unit by briefly pressing the UP
or DOWN button. Then press and hold the UP
and DOWN buttons simultaneously for around
3 seconds until the reset action begins (at half
speed). Let go of both buttons during the reset
action. Press and hold the UP button for around
10 seconds. The control unit will make two click-
ing sounds to indicate the start and one clicking
sound to indicate the end of the process. After-
wards let go of the button. Remove the mains
plug from the socket for at least 30 seconds.
Then reinsert the mains plug into the socket.
Finally perform a reset.
Note: The control unit is now in the same state
as when powering on for the first time.
The collision protection is not active during all
reset processes. Please be aware of potential
crushing hazards!
4. Factory settings (with manual switch with
memory function)
To reset the desk to its factory settings,
remove the mains plug from the socket for at
least 30 seconds. Then reinsert the mains plug
20
into the socket. The energy-saving mode must
be deactivated first through pressing the UP
or DOWN button shortly. Within <30 seconds
press the buttons M, 2, 3 simultaneously for
ca. 3 seconds until *S* appears. Then enter the
numbers 1, 2 and 3 and confirm the process
with the button M. The control unit confirms
a successful reset to the factory setting with
a double click and message E70. Remove the
mains plug from the socket for at least 30
seconds. Then reinsert the mains plug into the
socket. Finally perform a reset.
Note: The control unit is now in the same state
as when powering on for the first time.
The collision protection is not active during all
reset processes. Please be aware of potential
crushing hazards!
5. Energy-saving mode
The control unit will activate its energy-saving
mode after a few seconds of inactivity. You can
deactivate the energy-saving mode by pressing
the UP or DOWN button.
6. Manual desk height adjustment
- Press the UP button to raise the desk.
- Press the DOWN button to lower the desk.
- The motors continue to move for as long as you
press the button or until the maximum desk
height has been reached.
7. Activating the shelf stop or container stop posi-
tion (with UP/DOWN button)
- Bring the desk to the desired position.
- Press the UP+DOWN buttons for <1 sec and
then the UP button for 5 sec to activate the
shelf stop or container stop position.
- Motor control confirmed by double-click at
CST and by one-time click at SST
- Shelf stop position can only be activated in the
upper half of the stroke and container stop
position only in the lower half of the stroke
8. Deactivating the shelf stop or container stop
position (with UP/DOWN button)
- Bring the table to the shelf stop or container
stop position.
- Press the UP+DOWN buttons for <1 sec and
then the DOWN button for 5 sec to deactivate
the shelf stop or container stop position.
- Motor control confirmed by double-click at
CST and by one-time click at SST
9. Activating the shelf stop or container stop posi-
tion (for manual switch with memory function)
- Bring the desk to the desired position. The
position will be shown on the display.
- Press the button M to access the menu.
- Use the UP/DOWN button to select either
"SST" for the uppermost desktop height or
"CST" for the lowermost desktop height and
open by pressing the menu button M.
- Use the UP/DOWN button to select "ON" and
confirm by pressing M.
- The motor control unit will confirm your selec-
tion by making two clicking sounds.
10. Deactivating the shelf stop or container stop
position (for manual switch with memory
function)
- Press the menu button M to access the menu.
- Use the UP/DOWN button to select either
"SST" for the uppermost desktop height or
"CST" for the lowermost desktop height and
open by pressing the menu button M.
- Use the UP/DOWN button to select "OFF" and
confirm with M.
- The motor control unit will confirm your selec-
tion by making one clicking sound.
11. Saving further table top positions (only applica-
ble for manual switch with memory function)
- Bring the desk to the desire position. The posi-
tion will be shown on the display.
- Hold M for 1 to 3 seconds.
- Then press F1, F2, F3 or F4 within 3 seconds.
- The control unit will make two clicking sounds
to confirm that the position has been success-
fully saved.
12. Apply saved settings (only applicable for manual
switch with memory function)
Press and hold F1, F2, F3 or F4 until the desired
height is reached (see height indicator on the
display).
ophelis Technical documentation and operating instructions for CL Series sitting-standing workplaces
21