LP Tank Exchange
• Many retailers that sell Patio Ovens offer you the op-
tion of replacing your empty LP tank through an ex-
change service. Use only those reputable exchange
companies that inspect, precision fill, test and certify
their tanks. Exchange your tank only for an OPD safety
feature-equipped tank as described in the "LP Tank"
section of this manual on page 5.
• Always keep new and exchanged LP tanks in upright
position during use, transit or storage.
• Leak test new and exchanged LP tanks BEFORE
connecting to Patio Oven.
• Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap
on the cylinder valve outlet that is provided with the
cylinder valve. Other types of caps or plugs may result
in leakage of propane.
LP Tank Leak Test For Your Safety
Leak test must be repeated each time LP tank is
exchanged or refilled.
Do not smoke during leak test.
Do not use an open flame to check for gas leaks.
Oven must be leak tested outdoors in a
well-ventilated area and away from ignition sources,
such as gas-fired or electrical appliances.
During leak test, keep oven away from open flames
or sparks.
Use a clean paintbrush, a 50/50 mild soap and wa-
ter solution. Brush soapy solution onto areas
indicated by arrows in figure below. Leaks are
indicated by growing bubbles.
WARNING
!
If growing bubbles appear, do not use or move the LP
tank. Contact an LP gas supplier or your
fire department!
Do not use household cleaning agents.
to gas valve/hose/regulator components can result.
Connecting Regulator To The LP Tank
1. LP tank must be properly secured onto Patio
Oven. (Refer to assembly section on page 14.)
2. Turn all control knobs to the OFF position.
3. Turn LP tank OFF by turning OPD hand wheel
clockwise to a full stop.
4. Remove the protective cap from LP tank valve.
Always use cap and strap supplied with valve.
5. Hold regulator and insert
!
nipple into LP tank valve.
Hand-tighten the coupling nut,
holding regulator in a straight line
with LP tank valve so as not to
cross thread the connection.
Damage
6
Do not insert a POL transport
plug (plastic part with external
threads) into the Type 1 tank
valve outlet. It will defeat the
Safety Relief Valve feature.