Les langues disponibles

INSTALLATION MANUAL
GALEOW
Wiegand illuminated keypad
E] AUDIBLE SIGNAL
The audible signal is always enabled
in programming mode.
In factory default, the buzzer is disabled
when pressing a key. To enable the buzzer:
1. Enter in programming mode*.
2. Press A3:
- One beep is emitted.
- Press 0 to disable the audible signal.
- Press 1 to enable the audible signal.
- One beep is emitted to confi rm programming.
3. Remove the ST1 jumper:
- Two beeps are emitted to confi rm
exit from programming.
F] DECIMAL OR HEXADECIMAL MODE
1. Enter in programming mode*.
9] 26-BIT WIEGAND FORMAT
Chronograms
\DATA1
\CLOCK
\DATA0
* Please refer to the procedure to start programming at the start of this section
cdvi.com
18
cdvigroup.com
A3
0 logic
50 μs
2ms
2. Press A4 to enter in the mode
setting menu:
- One beep is emitted.
- Press 0 for a decimal mode, press 1
for a hexadecimal mode.
- One beep is emitted
to confi rm programming
3. Remove the ST1 jumper:
- Two beeps are emitted to confi rm
exit from programming.
- 4 beeps indicate a data
computing error.
G] EXTERNAL CONTROL OF THE BUZZER
The buzzer can be activated from an external input.
The control is done with a logic signal on the input.
Buzzer OFF
OV
1 logic
50 μs
Buzzer ON
Buzzer OFF
2ms
A4