7.3,
START.
• Turn the switch (1) to "
needs, lamp of line (2) lights on.
• Press the button (3), to turn on the resistance to heat
water in the coffee boiler.
• Wait until reaching the set temperature displayed on the
display (4) (90 ° C), and that the pressure in the steam
boiler is 1.2 bar (0.12 MPa) at this point the machine is
ready to be used.
7.4,
TEMPERATURE CONTROL OF COFFEE
AND STEAM BOILER.
To adjust the coffee temperature and pressure of the steam
boiler, proceed as follows:
• TEMPERATURE REGULATION
Press the button(1), the display (2) shows "t1", indicating
programming temperature of coffee; press the button (1),
to confirm the choice and act upon (1) and (3) to increase
or decrease the temperature.
• PRESSURE REGULATION
Press the button (1) twice, the display (2) shows "SP",
indicating the ability to set the vapor pressure (key 1
decreases, key 3 increases) max 1.5 bar.
At the end of the adjustment, it exits automatically from
the programming phase.
IMPORTANT: The electronic pressure control
with display is available on machines with
serial No. 58958 and subsequent.
" or "
" depending on the
3
4
1
3
1
2
2
25