Fault finding
Fault
The appliance is
"dead"!
Water collects in the
bottom of the
cabinet.
Vibration or
bothersome noise.
Compressor runs
continuously.
E1 is shown on the
display.
E2 is shown on the
display.
ULO is shown on the
display.
UHI is shown on the
display.
Possible cause
The appliance is switched off.
Power failure; the fuse is blown;
the appliance is not plugged in
correctly.
The defrost water pipe is
blocked.
The appliance is not level.
The appliance is resting against
other kitchen elements.
Containers or bottles inside the
cabinet are rattling against one
another.
High room temperature.
The upper sensor is
disconnected or short-circuited.
The lower sensor is
disconnected or short-circuited.
The mains voltage is lower than
184 V.
The mains voltage is higher
than 255 V.
12
Remedy
Press the on/off switch.
Check that power is connected.
Reset the fuse.
Clean the defrost water channel
and the drain hole on the rear
wall of the cabinet.
Level the appliance using a
spirit level.
Move the appliance away from
the kitchen elements or
appliances it is in contact with.
Move containers and/or bottles
apart.
Ensure adequate ventilation.
Call for service. The
temperature within the entire
cabinet is maintained at the
higher of the two setpoints until
the fault has been corrected.
Call for service. The
temperature within the entire
cabinet is maintained at the
higher of the two setpoints until
the fault has been corrected.