CT/LT Connection Details
LT
4
3
5
1
2
Pins
1 = Freq +ve
2 = Freq -ve
3 = Temp
4 = Temp
5 = N/C
Connecting cable (5m)
Extension cable (5m)
Connector (M12x1)
Note: For CT (5V) and CT (4-20mA):
l Use a shielded three core cable. Connect the shield to the transducer case.
l Use a UL class 2 or equivalent power supply.
l Use a 250mA, quick-blow fuse on Supply +In.
CT (5V)
4
3
5
1
2
Pins
1 = +In
2 = N/C
3 = 0 - 5V out
4 = N/C
5 = GND
N.B. N/C = Do not connect
FT10228-05
FT10229-05
FT9880
CT (4 - 20 mA)
4
3
5
1
2
Pins
1 = +In
2 = N/C
3 = 4 - 20mA out
4 = N/C
5 = GND
Sensor Recognition (3V)
2
1
3
4
5
Pins
1 - V Out
2 - N/C
3 - +In
4 - GND
5 - Sensor Recognition