Specification
Functional specification
Ambient temperature:
Fluid type:
Fluid temperature:
Accuracy:
Degree of protection*:
CT Electrical specification
Supply voltage (VS):
Current output:
Voltage output:
SR output:
EMC Environment:
LT Electrical specification
Output:
Impedance:
Inductance:
Construction material
Flow body:
Internal parts:
Transducer:
Seals:
For Flow and Pressure ratings see model table
-10 to 50 °C (14 to 122 °F)
Mineral oil to ISO 11158 category HM (for other fluid types please contact Sales).
-20 to 90 °C (-4 to 194 °F) continuous use
15 to 100% of range - 1% of indicated reading
Below 15% fixed accuracy of 1% of 15% of full scale (CT15 is 1% of full scale)
CT-SR – IP54 (EN60529)
CT-mA, CT-5V, LT – IP66 (EN60529)
*With cable connected
mA & 5V = 12 - 32 VDC, SR = 7 - 15 VDC
4 - 20 mA, 3 wire, max loop resistance = (VS x 50) - 200 ohms
0 - 5 VDC, current consumption = 10 mA, minimum load 20K ohms
0 - 3 VDC
This equipment is intended for use within industrial and residential environments and does
not suffer any degradation in operation when subjected to test conditions according to the
requisite standards.
Frequency - 20 -2000 Hz
3700 Ohm,
1kHz: 1.55H
600/750/800/1500 High tensile Aluminium 2014A T6
15/60/150/300/400 High tensile Aluminium 2011 T6
Aluminium, Steel, Stainless Steel
Body and nut -steel 212A42 electroless nickel plated, Lid and housing - Aluminium 2011 T3
FKM seals as standard EPDM are available - please consult sales office
3