Trouble or fault
The drill bit does not
rotate.
The drill bit cannot
be released.
Product does not
start.
14
English
Possible cause
The function selector
switch is not correctly
engaged, is set to "Chis-
eling"
, or is set to
"Chisel positioning"
The chuck is not pulled
back fully.
The side handle is not
fitted correctly.
Interruption in the elec-
tric supply.
The electronic restart
interlock is activated
after an interruption in
the electric supply.
The supply cord or plug
is defective.
The detachable supply
cord is not fitted cor-
rectly.
Generator with sleep
mode.
Action to be taken
▶ Move the function
selector switch to
the "Hammer drilling"
position while the
motor is not rotating.
.
▶ Pull the chuck back
as far as it will go and
remove the accessory
tool.
▶ Release the side
handle and refit it
correctly so that the
clamping band and
side handle engage in
the recess.
▶ Plug in another electric
tool or appliance
and check whether it
works.
▶ Switch the product off
and then on again.
▶ Have the supply cord
or the plug checked
by a trained elec-
trical specialist and
replaced if necessary.
▶ Fit the detachable
supply cord to the
power tool correctly.
▶ Apply a load to
the generator by
connecting a second
power consumer (e.g.
worklight). After this,
switch the product off
and then on again.
2134961
*2134961*